0

Your Cart is Empty

KEW2000 2000 KEWMATE POCKET MULTIMETER AC/ DC, 60AMP CURRENT CLAMP KYORITSU 46440011

KEW2000 2000 KEWMATE POCKET MULTIMETER AC/ DC, 60AMP CURRENT CLAMP KYORITSU 46440011

2000 KEWMATE POCKET MULTIMETER WITH OPEN CURRENT CLAMP SENSOR

Kyoritsu 2010 Multimeter Product Selection Guide (442kb PDFPDF filefile)

FEATURES:

  • Capable of measuring AC and DC currents up to 60A with OPEN CLAMP SENSOR.
  • 3400 counts with bargraph display.
  • Pocket size and heavy duty design.
  • Sleep function to save battery consumption.
  • Designed to international safety standard IEC 61010-1 CAT.III 300V

SPECIFICATIONS:

Range Measuring Range Accuracy
DC A 60A 0~60A plusmn;2%rdg±5dgt
AC A 60A 0~60A plusmn;2%rdg±5dgt (50/60Hz)
DC V 340mV
3.4V
34V
340V
600V
0~600V
(5 Autoranging)
%rdg±4dgt
AC V 3.4V
34V
340V
600V
0~600V
(4 Autoranging)
plusmn;1.5%rdg±5dgt
(50-400Hz)
Resistance
(Ω)
340Ω
(Continuity)
3.4kΩ
34kΩ
340kΩ
3.4MΩ
34MΩ
0~33.99MΩ
(6 Autoranging)
Buzzer sounds at 30Ω
plusmn;1%rdg±3dgt




(±5%rdg±5dgt)
(±15%rdg±5dgt)
Frequency
(Hz)
AC A 3.4kHz
10kHz
0~10kHz
(2 Autoranging)
%rdg±1dgt
AC V 3.4kHz
34kHz
300kHz
0~300kHz
(3 Autoranging)
%rdg±1dgt
MaximumAC/DC
Circuit Voltage
600V AC/DC (between line/neutral)
300V AC/DC (against earth)
Conductor Size Ø6mm max.
Withstand Voltage 3700V AC for 1 minute
Safety Standard IEC 61010-1 CAT.III 300V Pollution Degree 2
IEC 61010-2-031
IEC 61010-2-032
IEC 61326-1
Power Source Two R03 or equivalent (DC1.5V) batteries
Dimensions 128(L) × 87(W)× 21(D)mm
Weight 210g approx.
Accessories R03(1.5V) × 2
Instruction Manual
Optional Soft Case