$949.75
Fluke 374 FC delivers advanced troubleshooting performance and wireless connectivity
The Fluke 374 FC, part of the Fluke Connect family of wireless test tools, delivers the standard features you needfor everyday troubleshooting. Measure AC and DC current to 600 A with the fixed jaw clamp or add an optional iFlex®flexible current probe to measure all the way to 2500 A. Thelarge diameter and flexible design of the iFlex probe make it easier to measure around large conductors in tight spacesor to access tightly packed wires. You can also use the 374 FC to measure AC and DC voltage to 1000 V and resistance to 6000 Ω.
Use wireless connectivity to keep a safe distance
The 374 FC is Fluke Connect-enabled to wirelessly transmit results via Bluetooth to Apple and Android devices.That means you can read the results out of the arc flash zone, wearing less PPE. You can even save results to the cloud and create and send reports in email right from the field. Or converse in real-time with ShareLive™ video calls.
Versatile feature set
With True-RMS AC voltage and current measurements, the 374 FC enables you to accurately troubleshoot non-linear signals. And you can log and trend measurements to pinpoint intermittents while you are performing other tasks. The Fluke 374 FC Clamp Meter is the direct replacement for the Fluke 374 Clamp Meter.
Other useful capabilities:
Includes:
General Specifications | ||||
AC Current via Jaw | ||||
Range | 600.0 A | |||
Resolution | 0.1 A | |||
Accuracy | 2% ±5 digits (10 Hz to 100 Hz) 2.5% ±5 digits (100-500 Hz) | |||
Crest Factor (50 Hz/60 Hz) | 2.5 @ 600 A Add 2% for C.F. >2 | |||
AC Current via Flexible Current Probe | ||||
Range | 2500 A | |||
Resolution | 0.1 A (≤ 600 A) 1 A (≤ 2500 A) | |||
Accuracy | 3% ±5 digits (5 – 500 Hz) | |||
Crest Factor (50/60Hz) | 2.5 at 1400 A 1.42 at 2500 A Add 2% for C.F. > 2 | |||
Position Sensitivity | ||||
![]() | Distance from Optimum | |||
i2500-10 Flex | i2500-18 Flex | Error | ||
A | 0.5 in (12.7 mm) | 1.4 in (35.6 mm) | ±0.5 % | |
B | 0.8 in (20.3 mm) | 2.0 in (50.8 mm) | ±1.0 % | |
C | 1.4 in (35.6 mm) | 2.5 in (63.5 mm) | ±2.0 % | |
Measurement uncertainty assumes a centralized primary conductor at the optimum position, no external electrical or magnetic field, and within operating temperature range. | ||||
DC Current | ||||
Range | 600.0 A | |||
Resolution | 0.1 A | |||
Accuracy | 2% ±5 digits | |||
AC Voltage | ||||
Range | 1000 V | |||
Resolution | 0.1 V (≤600.0 V) 1 V (≤1000 V) | |||
Accuracy | 1.5% ±5 digits (20 Hz to 500 Hz) | |||
DC Voltage | ||||
Range | 1000 V | |||
Resolution | 0.1 V (≤600.0 V) 1 V (≤1000 V) | |||
Accuracy | 1% ±5 digits | |||
mV dc | ||||
Range | 500.0 mV | |||
Resolution | 0.1 mV | |||
Accuracy | 1% ±5 digits | |||
Resistance | ||||
Range | 6000 Ω | |||
Resolution | 0.1 Ω (≤600 Ω) 1 Ω(≤6000 Ω) | |||
Accuracy | 1% ±5 digits | |||
Capacitance | ||||
Range | 1000 μF | |||
Resolution | 0.1 μF (≤ 100 μF) 1 μ F (≤ 1000 μF) | |||
Accuracy | 1% ±4 digits | |||
Mechanical Specifications | ||||
Maximum voltage between any terminal and earth ground | 1000 V | |||
Batteries | 2 AA, NEDA 15A, IEC LR6 | |||
Operating temperature | -10 °C to +50 °C | |||
Storage temperature | -40 °C to +60 °C | |||
Operating humidity - non-condensing (< 10°C) | ≤90% RH (at 10 °C to 30 °C) ≤75% RH (at 30 °C to 40 °C) ≤45% RH (at40 °C to 50 °C) | |||
Operating altitude | 3000 m | |||
Storage altitude | 12,000 m | |||
Size (L x W x H) | 249 x 85 x 45 mm | |||
Weight | 395 g | |||
Jaw opening | 34 mm | |||
Flexible current probe diameter | 7.5 mm | |||
Flexible current probe cable length (head to electronics connector) | 1.8 m | |||
Safety | IEC 61010-1, Pollution Degree 2 IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V IEC 61010-2-033:CAT III 1000 V / CAT IV 600 V | |||
IP rating | IEC 60529: IP30, non-operating | |||
Radio Frequency Certification FCC ID | T68-FBLE IC:6627A-FBLE |
Please Note: Online stock only for this item. Shipping at checkout for this item may be an estimate only and may apply only to some metro areas or to a specific distance from supply location. Local pickup may be available on some items by prior arrangement. Shipping charges may still apply for this item for Click and collect in store orders as this item may still need to be shipped to us for collection from the local pickup location.
Please use the contact us form to get an accurate shipping quote based on your order quantity and location to avoid order cancellation charges.