0

Your Cart is Empty

T6600 600V 200A AC/DC MULTI TESTER WITH FIELDSENSE TECHNOLOGY FLUKE T6-600

T6600 600V 200A AC/DC MULTI TESTER WITH FIELDSENSE TECHNOLOGY FLUKE T6-600

Overview

T6600 600V 200AMP AC/DC MULTI TESTER WITH FIELDSENSE TECHNOLOGY

Measure voltage without test leads

Measure voltage up to 600 V ac through the open fork, without test lead contact to live voltage.+ Without opening covers or removing wire nuts. On wires up to AWG 4/0 (120 mm2), carrying as much as 200 A. It will change your job. Safer. Faster. Easier.

Features

  • FieldSense technology for ac voltage, current and frequency measurement without making electrical contact to live voltage+
  • 1 to 600 V ac
  • 0.1 to 200 A ac
  • Resistance 1 ? to 2000 ?
  • Works with wires up to AWG 4/0 (120 mm2) with a 17.8 mm jaw opening
  • HOLD button temporarily freezes the reading for easy viewing
  • Easy to read display with backlight
  • Accepts optional Fluke TPAK Magnetic Meter Hanger for convenient operation
  • Standard two-year warranty; extendable to 4 years

Specifications

Measurement Specifications

Function

Requires
test leads

Range

Resolution

Accuracy[1]

FieldSense
ac voltage

No

600 V

1 V

±(3% + 3 counts) 45 Hz - 66 Hz[2][3]

FieldSense
ac current

No

200.0 A

0.1 A

±(3% + 3 counts) 45 Hz - 66 Hz

FieldSense
frequency (Hz)

No

1 Hz

±(1% + 2 counts)[3]

Volts ac

Yes

600 V

1 V

±(1.5% + 2 counts) 45 Hz - 66 Hz

Volts dc

Yes

600 V

1 V

±(1% + 2 counts)

Resistance

Yes

2000 ?

1 ?

±(1% + 2 counts)

Safety

600 V CAT III

Accuracy[1]: ± ( [ % of reading] + [number of least significant digits] ). Accuracy is specified for 1 year after calibration, at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC measurements are ac-coupled, RMS responding.
Accuracy[2]: Add 3 % without an external ground connection. External ground connection required for user wearing insulated gloves, standing on an insulated ladder, or otherwise insulated from earth ground.
Accuracy[3]: FieldSense is specified from 16 V to 100 % of range.

General Specifications

Calibration

1-year calibration cycle

Dimensions

61.1 x 259.3 x 43.8 mm

Jaw opening

17.8 mm

Weight

0.35 kg (0.78 lb)

Temperature
Operating:
Storage:

-10 °C to +50 °C (14 °F to 122 °F)
-30 °C to +60 °C (-22 °F to +140 °F)

Altitude
Operating:
Storage:

2,000m (6,562 feet)
10,000 m (32,808 feet)

Relative Humidity

0% to 90%, 5 °C to 30 °C (41 °F to 86 °F)
0% to 75%, 30°C to 40 °C (86 °F to 104 °F)
0% to 45%, 40°C to 50 °C (104 °F to 122 °F)

Battery Type and Life

2 x AA (IEC LR6); 360 hours continuous, typical; 200 hours using FieldSense

Temperature coefficient

0.1 x (specified accuracy) / °C for <18°C or >28 °C
(< 64.4 °F or > 82.4 °F)

Safety

IEC/EN 61010-1: Pollution Degree 2

Electromagnetic Environment

IEC/EN 61326-1: Portable

 

Please Note: Online stock only for this item. Shipping at checkout for this item may be an estimate only and may apply only to some metro areas or to a specific distance from supply location. Local pickup may be available on some items by prior arrangement. Shipping charges may still apply for this item for Click and collect in store orders as this item may still need to be shipped to us for collection from the local pickup location.

Please use the contact us form to get an accurate shipping quote based on your order quantity and location to avoid order cancellation charges.