Sold Out
Online Stock Only.
For "click and collect" orders at Lynbrook store the shipping fee will still apply on collection for items not stocked at the Lynbrook store.
High quality open style toroidal transformers with a single 230V a.c. 50/60Hz primary winding. Twin secondary windings may be connected in series or parallel or used independently.
Important Installation Note
Each transformer is supplied with a dished washer and protection pads for single hole fixing. Ensure that the padsare fitted above and below the transformer winding and that the dished washer is on top of the upper pad. Do not overtighten the fixing bolt (not supplied) as this could damage the winding.
Under no circumstances should both ends of the fixing bolt contact a metal chassis or frame as this would create a'shorted turn' causing irreparable damage.
NOTE:
Secondary Current A - current available when secondaries are connected in parallel
Secondary Current B - current available when secondaries a reconnected in series.
Rated VA |
Regulation % Typical |
Temperature Rise [K] |
Dimensions* Diameter [mm] |
Height [mm] |
Weight [Kg] |
15 | 16 | 26 | 60 | 31 | 0.30 |
30 | 18 | 40 | 70 | 32 | 0.45 |
50 | 14 | 42 | 80 | 33 | 0.65 |
80 | 14 | 53 | 93 | 38 | 0.90 |
120 | 10 | 52 | 93 | 46 | 1.20 |
160 | 9 | 55 | 105 | 42 | 1.50 |
225 | 8 | 60 | 112 | 47 | 1.90 |
300 | 8 | 60 | 115 | 58 | 2.30 |
500 | 6 | 68 | 136 | 60 | 3.50 |
625 | 5 | 67 | 136 | 68 | 4.30 |
800 | 5 | 69 | 162 | 60 | 5.10 |
1000 | 5 | 72 | 162 | 70 | 6.50 |
* Allow extra 4mm for mounting kit, allow extra 5mm where leads emerge
Leads: PVC insulated 150mm long.
Secondary voltage tolerance: <1% at nominal input
Overall insulation category: Class A 105°C
Maximum ambient operating temperature +40°C
Neoprene pads: 5kV isolation
Meets all requirements of Class E (120°C)